Home Ordering UK/EU Ordering USA Contact Us
Sterling Power Products logo
Products
Alternators
Alternator Protector
Alternator Regulators
Alternator to Battery Chargers
Alternator Splitting Systems
Battery Chargers & Maintainers
Battery Charging Link
Connectors
Battery Desulphation Unit
Battery to Battery Chargers
Crossover Switch
Galvanic Isolators /
Fail Safe Zinc Savers
Gold Plated Accessories
High Powered Distribution Box
Inverters
Inverter-Charger Combis
Technical Specifications
Combined Inverter Chargers Comparisons
Isolator Switch
Pneumatic Tank Gauge
Power Management Panel
Solar Regulators
Split Charge Diodes
System Diagnostics
Waterproof Battery Chargers
Waterproof Battery to Battery Charger
Wildside
High Resolution Photos
Where to Buy
Downloads
Datasheets
Support
About Sterling Power Products
Press & News
Sterling Power USA
Sitemap

Technical Specifications

What does the Pro Combi range offer?

On the battery charger side

  • 4 step constant current battery charging
  • 8 pre set battery type selector plus de-sulphation
  • powerful charge rate
  • will charge totally flat batteries
  • PFC, draws about 30% less power than conventional units

On the crossover side

  • 20 m/s crossover time, will not to lose any equipment due to power loss
  • 30 amp through current ability on all models
  • twin 30 amp / single 50 amp on the 3500 watt models

On the inverter side

  • high overload ability
  • high temperature rating
  • low quiescent current
  • power saver mode to automatically reduce power
  • allows through power even with no batteries connecte

On the remote control

  • ability to switch the unit on/off
  • ability to select or de select power saver mode

General

  • removable local panel to give remote control with waming and function I.e.d.
  • remote on/off plus remote power saver on/off
  • 10 metres remote cable
  • almost 20 alarms/ warnings/and information

General Features for ProCombi Q

  • Battery bank size: autodetected / auto program adjusted
  • Remote control: front control panel removable as remote
  • Size (mm) (w x h x l): 185 x 180 x  430 (1600 & 2500)
  • Weight: 18kg (1600); 20kg (2500)

General Features for ProCombi S

  • Remote control: front control panel removable as remote
  • Size (mm) (w x h x l): 185 x 180 x  430 (1600 & 2500); 227 x 180 x 512 (3500)
  • Weight: 20kg (1500); 20kg (2500); 24kg (3500)

There are 2 main models the Pro Combi Q for quasi-sinewave) and the Pro Combi S (for Pure-sinewave). So the simple question is what best suits your needs?

Pro Combi Q, (quasi-sine model) suitable for most installations, where you would use a microwave, fridge, hair dryer, vacuum cleaner, kettle, computer, etc The vast majority of products will run on quasi-sinewave.

Pro Combi S ( sine wave model ) where all the above plus washing machines, bread makers , thyristor controlled equipment are used - then sinewave is required
To make the choice even simpler, we have a 6 months exchange/upgrade policy.

If you purchase a Pro Combi Q and find there is some equipment that you cannot run due to the Quasi Sinewave and require Pure Sinewave, Sterling are happy to up-grade your quasi-sine unit for sinewave with the only cost being the difference between the 2 products (unit must be sent direct to Sterling and in good condition).

  ProCombiQ ProCombiS
General specification
Input wave form Sinusoidal Pure sine wave
Nominal voltage Input 230 v a/c Input 230 v
Low voltage trip 184v+/- 4% a/c 184v+/- 4%
Minimum engage voltage 194v +/- 4% voltage 194v +/- 4%
High voltage trip 253v +/- 4% 253v +/- 4%
High voltage re engage 243v +/- 4% 270 v rms 243v +/- 4%
Max input a/c voltage 270 v rms 270 v rms
Nominal input frequency 50hz or 60hz auto detect 50hz or 60hz auto detect
Low frequency trip 7 hz for 50 hz, 58 hz for 60 hz 47 hz for 50 hz, 58 hz for 60 hz
High frequency trip 53 hz for 50 hz, 62 hz for 60 hz 53 hz for 50 hz, 62 hz for 60 hz
Output wave form (on bypass mode) same as input (on bypass mode) same as input
Overload protection Circuit breaker Circuit breaker
Short circuit protection Circuit breaker Circuit breaker
Transfer switch rating 30 amp 1500-2500 w = 30 amp
3500 w= 50 amp
Efficiency online transfer mode 96%+ 95%+
Line transfer time 20 ms 20ms
Bypass without battery connected yes Yes
Max bypass current 30 amps 30 amps
Bypass overload current 35 amps: Alarm 35 amps: Alarm
Inverter specification / output
Output wave form Modified Sine Wave/ Quasi sine wave Pure sine wave
Output continuous power watts 1600
2500
continuous 2100 (2500 30 min), 3200 ( 3500 30 mins)
Output continuous power VA 2400
3600
3100
5000
Power factor 0.9 – 1.0 0.9 – 1.0
Nominal output voltage rms 230vac 230vac
Max voltage rms 260vac 260vac
Output voltage regulation +/- 10% rms +/- 10% ms
Output frequency 50hz+/-0.3hz or 60hz+/-0.3hz 50hz+/-0.3hz or 60hz+/-0.3hz
Transient response time <150ms;0% to 100% RCD load <150ms;0% to 100% RCD load
Nominal efficiency >85% >88%
Surge rating 1500model=4500va
2500model = 7200va
PQS1500 = 4500va
PQS2500 = 7200va
Online current consumption at 12 v/24v
12v: 1.8a 24: 0.9a not available until March 2008
Power saver mode current consumption 12v: 0.4a 24v: 0.2a not available until March 2008
Short circuit protection yes, less than 3 cycles yes, less than 3 cycles
Inverter specification / input
Nominal input voltage 12 or 24 v depending on model 12 or 24 v depending on model
Minimum start voltage 10 v for 12 v model 20v for 24 v 10 v for 12 v model 20v for 24 v
Low battery alarm 10.5v for 12 v model 21v for 24 v 10.5v for 12 v model 21v for 24 v
Low battery trip 10 v for 12 v model 20v for 24 v 10 v for 12 v model 20v for 24 v
High voltage alarm 15.5 for 12v model 30v for 24 v 15.5 for 12v model 30v for 24 v
Power saver Below 20 watts when enabled Below 20 watts when enabled
Power saver can be switched on/off on remote control Same switched on/off on remote control
Charger mode specification
Input voltage range 196-245 v ac 196-245 v ac
Output voltage Dependent on battery type selection Dependent on battery type selection
Output current 12 v model 1600: 40A; 2500: 50A 1500: 40A; 2500: 70A; 3500: 100A
Output current 24 v model 1600: 20A; 2500: 25A 1500: 20A; 2500: 35A; 3500: 50A
Initial voltage for start up 0-15v for 12 v x 2 /24v 0-15v for 12 v x 2 /24v
Over charge protection shutdown 15.712v x2for24v 15.712v x2for24v

 

ProCombi Q and ProCombi S
Charger curves (4 stage constant current) battery types
4 step digital controlled progressive charge
Battery type Charge (v) Float (v)  X 2 for 24 v
Gel USA 14.0 13.7  
AGM 1 14.1 13.4  
AGM2 14.6 13.7  
Sealed Lead Acid 14.4 13.6  
Gel Euro 14.4 13.8  
Open Lead Acid 14.8 13.3  
Calcium 15.1 13.6  
De-Sulphation 15.5 for 4 hours    

 

top